Dry Type Cast Resin Transformer

Looking for high-quality Dry Type Cast Resin Transformers? Trust our factory for reliable and efficient solutions. Explore our range now!

Request a Quote
  • Dry Type Cast Resin Transformer
  • Dry Type Cast Resin Transformer

PRODUCTS DETAILS

Product Description

The SCB10 epoxy resin cast dry-type transformer is made of high-quality materials and scientific formula, using advanced production testing equipment according to strict processes. The product has the characteristics of high reliability and long service life. According to different use environments, shells with different protection levels or no shells can be configured. Suitable for important or special environmental places such as high-rise buildings, commercial centers, airports, tunnels, chemical plants, nuclear power plants, ships, etc.


Product features:

1. It is safe, fireproof and pollution-free.

2. Adopting German HTT technology, it has high mechanical strength, strong short circuit resistance, small partial discharge, good thermal stability, high reliability and long service life.

3. Low loss, low noise, excellent energy saving effect, maintenance free.

4. It has good heat dissipation performance and strong overload capacity.

5. Good moisture-proof performance, suitable for operation in high humidity and other harsh environment.

6. It can be equipped with perfect temperature monitoring and protection system. The intelligent signal temperature control system can be used for automatic monitoring.

7. The working temperature of three-phase winding can be displayed in circuit, and the fan can be started and stopped automatically, and alarm and trip functions can be set.

8. Small size, light weight, less space occupied and low installation cost.


Ambient temperature:

1. Max temperature +40℃,Daily average max temperature +30℃,Max yearly average temperature +20℃.

2. The elevation should not be beyond 1000m.

3. The voltage waveform for the power supply is almost like sine wave and three-phase power supply voltage is approximately symmetric.

4. Special conditions of use

Provided in the clients’ inquiry sheet in detail (such as, high elevation and ambient temperature higher than 40℃, etc.)


Cooling System

1. The product generally adopts natural air cooling (AN) and it can continuously output 100% rated load. For the transformers of any protection grade, they can be equipped wind cooling system. If necessary, forced air cooling (AF) can be adopted to improve output power for emergent use in the case of dropping coil temperature or short-time overload.

2. If the output load rate is more than 65% or the ambient temperature is very high, put it into the fan and cool the coil, which effectively decreases the coil’s on-load loss and drops its hot-point temperature-rise in order to reach double function, that is, energy conserving and prolonging the coil’s lifespan.

3. It is advised that the fan is started via automatic control of thermostat. In default, the thermostat of the company sets the transformer to start the fan under 120℃ and 100℃ fan stopping, 140℃ alarm and 155℃ tripping, so the clients need not adjust in general.

4. For normal running, every 1 kW loss (Po+Pk) needs 4m3/min ventilation rate in general. When the transformer is installed in basement or other environments with worse ventilation ability, a heat dissipation and ventilator should be added to help air circulation.

Warning: If the transformer starts the wind cooling equipment and it is run beyond nameplate’s capacity, check the transformer’s actual loss under real running load to confirm whether the ventilation of the transformer room meets the requirement. If the ventilation is not enough, the transformer’s heat dissipation might be difficult and the transformer will suffer serious influence.


Technical Data

Rated Capacity
(kVA)

Rated Voltage (KV)

Vector Group

Short-Circuit Impedance
(%)

Loss(kW)

No-load Current
(%)

Weight(kg)

Outline Dimension
(L×W×H,mm)

Enclosure Dimension
(L×W×H,mm)

High voltage (KV)

High voltage tapping range

Low voltage (KV)

No-load Losses

Load Losses

30

6KV 6.3KV
6.6KV 10KV 11KV 13.8KV

±5% 或
±2× 2.5%

0.4

Dyn11
Yyn0

4

0.195

0.71

2.5

340

780×450×790

900×900×1080

50

0.275

0.95

2.2

430

840×450×855

1000×900×1150

80

0.375

1.385

2.1

560

900×600×885

1060×1000×1180

100

0.405

1.58

1.9

720

920×600×900

1080×1000×1200

125

0.475

1.895

1.8

830

980×600×960

1140×1000×1260

160

0.55

2.14

1.8

940

1040×710×1000

1240×1050×1300

200

0.63

2.54

1.6

1250

1070×710×1200

1270×1050×1450

250

0.73

2.77

1.5

1450

1140×710×1245

1340×1050×1550

315

0.89

3.485

1.4

1600

1180×710×1300

1360×1050×1600

400

0.99

4.01

1.4

1980

1380×960×1425

1540×1150×1720

500

1.175

4.91

1.3

2300

1400×960×1515

1570×1150×1810

630

1.36

5.91

1.3

2570

1440×960×1595

1610×1150×1900

630

Dyn11
Yyn0

6

1.315

5.995

1.2

2550

1500×960×1405

1660×1150×1700

800

1.54

6.99

1.2

2810

1560×960×1575

1680×1150×1870

1000

1.79

8.17

1.1

3210

1640×960×1685

1750×1200×1980

1250

2.115

9.75

1.1

3400

1700×1255×1815

1850×1400×2120

1600

2.48

11.8

1

4150

1800×1255×1980

1920×1400×2280

2000

3.36

14.535

0.9

5600

940×1255×2110

2050×1450×2420

2500

4.05

17.27

0.8

6300

2060×1255×2350

2170×1450×2750


1


2


3


4


Hot Products

Single Phase Auto Transformer

Single Phase Auto Transformer

Dry Type Transformer With On Load Tap Changer

Dry Type Transformer With On Load Tap Changer

Outdoor Vacuum Circuit Breaker

Outdoor Vacuum Circuit Breaker

Oil Filled Transformer

Oil Filled Transformer

KYN28 Switchgear

KYN28 Switchgear

KYN61 40.5 Switchgear

KYN61 40.5 Switchgear

24kV Three Phase Oil Fill Power Transformer

24kV Three Phase Oil Fill Power Transformer

Cable Distribution Cabinets

Cable Distribution Cabinets

Withdrawable Switchgear

Withdrawable Switchgear

33KV Transformer

33KV Transformer

SGB Dry Type Transformer

SGB Dry Type Transformer

11kv Substation

11kv Substation

VS1 Vacuum Circuit Breaker

VS1 Vacuum Circuit Breaker

Dry Type Cast Resin Transformer

Dry Type Cast Resin Transformer

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours